On most London rear extensions the roof is decided by height before it is decided by taste. The extension has to fit under the first-floor windows, it often sits within 2 metres of a boundary, and under permitted development its eaves there can be no higher than 3 metres. A flat roof usually fits those numbers more easily. A pitched roof, often a lean-to against the back wall, can work where there is enough height or where the extension has planning permission. This guide sets out what decides it. Planning limits were checked against the Planning Portal and insulation figures against Approved Document L on 17 November 2026.
Which roof is allowed under permitted development?
Both are, as long as the extension stays within the limits. For a single-storey rear extension the maximum height is 4 metres, but where the extension comes within 2 metres of the boundary "the height at the eaves cannot exceed three metres". On a terraced house the extension usually runs along the boundary on at least one side. A lean-to with 3 metre eaves on the boundary and a 4 metre top against the house is possible, but only if the first-floor window sill is high enough to clear it.
Two other rules affect the roof. The extension cannot be higher at the eaves than the existing house eaves, and the work cannot include "any alteration to the roof of the existing house". A pitched roof that ties into the main roof slope therefore needs planning permission. If the extension needs a planning application anyway, the council’s design guidance for rear extensions decides the roof, and that guidance differs from borough to borough. See our permitted development guide for the full limits.
Will a pitched roof fit under the first-floor window?
That is the question that decides most London extensions. A lean-to rises from the eaves to the wall of the house, and the top has to meet the wall below the sill of the window above, with room for the flashing. If the eaves sit at 2.5 to 3 metres and the extension is 3 metres deep, the roof has to climb to meet the wall at a height that often lands across the window.
The options when it does not fit are a lower pitch, which limits the roof covering, a flat roof, or moving the window. The maker of each tile or slate states a minimum pitch for it, and many traditional clay tiles and natural slates need a steeper slope than a shallow lean-to can give. Ask for the product and its minimum pitch before you settle on the look.
How do flat and pitched roofs compare?
| Point | Flat roof compared with pitched roof |
|---|---|
| Height | A flat roof keeps the whole extension at one height, usually lower overall. A pitched roof needs more height at the house wall |
| Ceiling inside | A flat roof gives a flat ceiling. A pitched roof can be left open as a vaulted ceiling, which gives height in the middle of the room |
| Daylight | A flat roof takes flat rooflights or a lantern anywhere on the roof. A pitched roof takes roof windows on the slope |
| Water | A flat roof has a slight fall to outlets and relies on its membrane. A pitched roof sheds water over tiles or slates and is more forgiving of small faults |
| Covering | Flat: single ply membrane such as EPDM, GRP fibreglass, or a reinforced bitumen system. Pitched: tiles or slates to match the house |
| Upkeep | A flat roof needs its outlets and gutters kept clear and its edges checked. A pitched roof needs slipped tiles and flashings checked |
| Look on a period house | A flat roof with a parapet reads as a modern addition. A lean-to in matching slate can look like part of the original house |
Is a flat roof less durable than a pitched one?
Not if it is designed and built properly, and that is where flat roofs differ most. Their weak points are the edges, the outlets and the joints around rooflights, so the detail drawings matter more than the membrane brand. Each membrane maker publishes its own guarantee terms and approved installers. Ask which system is being used, whether the installer is approved by its maker, and what the guarantee covers. Water that sits on a flat roof after rain usually points to the falls, which a new membrane will not fix.
Do both roofs need the same insulation?
Yes. Table 4.2 of Approved Document L, Volume 1 sets a maximum U-value of 0.15 W/m²K for a new roof on an extension, flat or pitched. A flat roof is usually built as a warm roof, with the insulation above the deck and the membrane on top, which adds depth at the edges. A pitched roof can take insulation between and under the rafters. Rooflights have their own limit of 2.2 W/m²K.
Which roof suits a kitchen extension?
Most kitchen extensions on London terraces have flat roofs, because the room needs daylight in the middle, the extractor and soil pipes need a route, and the extension has to clear a first-floor window. A lean-to with roof windows suits a narrow side return where the slope can face the sun and the house wall gives enough height. On a wide rear extension a pitched roof often turns into a hipped or gabled roof, which is more height and more cost again.
What can go wrong at the junction with the house?
The junction between the extension roof and the house wall is the most common source of leaks on both types. On a lean-to it is the flashing where the slope meets the brickwork; on a flat roof it is the upstand and flashing along the same wall. Both need the flashing let into a mortar joint and, in a cavity wall, a cavity tray above it, as in the drawing below. On a terraced house check also how the roof drains: an outlet that discharges onto the neighbour’s side needs agreement and, often, a party wall notice.

On Malvern Mews, which Martynas Vaitaitis project-managed before Vayton was established (developer Modernation Ltd, completed December 2024), the roof combined sedum green-roof areas and drainage layers with junctions to rooflights, glazing and parapets, and each of those had to be detailed together with the wall build-ups and insulation. The Malvern Mews project page has the photographs and the build in detail.