HMO requirements in London come from two places. National law sets the floor for a house in multiple occupation (HMO): minimum bedroom sizes, a licence for larger HMOs and a planning use class. Each council then publishes its own standards for room sizes, kitchens, bathrooms and fire precautions, and its figures are often higher. A conversion has to be built to the council's figures.
This guide is for landlords planning a conversion. It covers England, with the detail for four London councils: Camden, Ealing, Croydon and Newham. We read every figure on 19 November 2026 from the legislation and the councils' own pages, which are linked where they are used. Councils revise their standards, so check the current page for your borough before you fix a layout. We are builders, and a licensing question about one property is for the council.
What counts as an HMO?
GOV.UK gives the test in two parts. A home is an HMO if "at least 3 tenants live there, forming more than 1 household" and they share a toilet, bathroom or kitchen. A household is a single person, or members of the same family who live together. A large HMO has at least 5 tenants forming more than one household.
Which HMOs need a licence?
Every large HMO in England needs a licence from the council. Camden describes the national rule as covering "most properties occupied by 5 or more people forming 2 or more households, regardless of the number of storeys".
Several London councils also run an additional licensing scheme for smaller HMOs. Three that were in force on 19 November 2026:
- Camden: a scheme that came into force on 8 December 2025 and applies to "any property occupied by 3 or more people forming 2 or more households"
- Croydon: an Additional HMO Licensing Scheme for HMOs of 3 or 4 people, in force from 25 September 2026
- Newham: a scheme launched on 1 January 2023 for an HMO "shared by three or four people forming two or more households"
These schemes run for a fixed term, so the list changes. Camden points landlords to the Greater London Authority's Property Licence Checker to see what applies at an address.
Do you need planning permission for an HMO?
In some London boroughs, yes. Planning law puts a family home in use class C3 and a small HMO in class C4, which the Use Classes Order defines as "use of a dwellinghouse by not more than six residents" as an HMO. Nationally the change from C3 to C4 is permitted development, so it needs no application. A council can remove that right in its area with an Article 4 direction. Croydon and Ealing have both done so:
- Croydon: "any HMO of 3 to 6 people created after 28 January 2020 (C4 Use Class) must have appropriate planning consent"
- Ealing: planning permission is needed to change a C3 dwelling to a C4 HMO, in Perivale ward from 30 October 2024 and across the rest of the borough from 14 November 2025, with separate directions for the OPDC area
An HMO for seven or more people falls outside class C4. Croydon says these larger HMOs need "appropriate planning consent" and that this "has been in place for many years".
Planning permission and the licence are separate decisions, but one affects the other. Croydon says it takes the planning status into account and may refuse a licence or grant one for a shorter term, "commonly one year". Sort out planning before you spend money on the building.
What are the minimum room sizes for an HMO?
In an HMO that needs a licence, the national minimum for a bedroom is 6.51m² for one person over 10 and 10.22m² for two. A room smaller than 4.64m² cannot be used for sleeping at all, and any floor area where the ceiling is lower than 1.5m is not counted. These are conditions that the 2018 regulations put into every HMO licence in England.
London councils publish their own figures, and those depend on how the house is let and what shared space it has. This table gives the smallest bedroom each standard allows, for one person and for two.
| Standard | One person / two people |
|---|---|
| National licence condition | 6.51m² / 10.22m² |
| Camden, shared kitchen, shared living room of at least 10m² and "cohesive living" | 7.1m² / 10.2m² |
| Camden, kitchen in a separate room | 9m² / 11m² |
| Camden, kitchen facilities inside the bedroom | 12m² / 14m² |
| Ealing, licensing page | 6.5m² / over 10.2m² |
| Ealing, bedroom with cooking facilities | 10.2m² / 13.5m² |
| Ealing, planning guidance | 7.5m² / 11.5m² |
| Croydon, bedsit letting with a shared kitchen | 10m² / 15m² |
The Camden rows come from its standards for houses and flats with shared facilities. Its lowest figures apply only where there is a shared living room of at least 10m² as well as the shared kitchen "and where there is cohesive living". The single figure rises to 7.3m² where the room has a wash hand basin. Camden's 10.2m² for two is a shade under the national 10.22m², and the licence condition still applies.
Ealing uses two sets of numbers. Its licensing page, dated 24 July 2024, follows the national sizes. Its planning guidance, dated 12 November 2025, asks for 7.5m² and 11.5m², and for a combined living, dining and kitchen space of 25m² for three people, 27m² for four, 29m² for five and 31m² for six. Where a conversion in Ealing needs planning permission, draw it to the planning figures.
Croydon publishes its bedsit standard, dated 1 October 2024, and says of other types: "we will advise you of the standard to meet for your specific HMO property when you make an application and we have seen the floor plan/layout". The same standard sets a ceiling height of 2.3m, or 2.14m over at least 75% of an existing attic room.
How many kitchens and bathrooms does an HMO need?
The common rule in Camden, Ealing and Croydon is one set of kitchen facilities for every five people, with bathrooms counted in much the same steps. In those boroughs the sixth tenant is the expensive one, because that is where a second kitchen and a second bathroom come in.
| Council | Kitchens and bathrooms |
|---|---|
| Camden | One full set of kitchen facilities for up to 5 people and two sets for 6 to 10. One bathroom with a WC for up to 4 people; for 5, two bathrooms or a bathroom plus a separate WC with a basin; for 6 to 10, two full sets. |
| Ealing | "1 kitchen and 1 bathroom is required per 5 occupiers." |
| Croydon, bedsit standard | Each shared kitchen is used by no more than 5 people. One bathroom or shower room for 5 people and two for 6 to 10, with two WCs for 6 to 10, one of them separate from the bathroom. |
The detail goes further than the count. Camden asks for 2.8 linear metres of worktop in a kitchen shared by five and at least five double sockets for each set of kitchen facilities. Camden and Croydon both want a bathroom no more than one floor away from any bedroom. Camden wants an extract fan in every bathroom that runs on for at least 15 minutes or is controlled by a humidistat. Newham puts its standards for all private rented homes, HMOs included, in one document, so read its kitchen and bathroom sections for a house there.
What fire safety work does an HMO need?
More than a family home needs, and the council decides how much for each house. Croydon says fire is risk assessed "on a property by property basis", looking at the number of storeys, the number of occupiers, the escape routes and where the cooking is done. Camden requires all work to be carried out "in accordance with LACORS national guidance on fire safety and the latest edition of BS5839:Part 6".
Croydon's bedsit standard lists what may be asked for:
- a 30 or 60 minute fire protected route of escape
- fire separation between units of accommodation, including walls and ceilings
- fire doors fitted with cold smoke seals, intumescent strips and self-closing devices
- automatic and manual fire detection systems
- emergency lighting
Newham's standard for all private rented homes sets a minimum for alarms: mains-wired smoke alarms with battery backup, to BS 5839-6:2019, in the hallway, on each landing and in any high risk room such as a living room, with a heat alarm in the kitchen and all of them linked so they sound together.
On site, a protected route means the walls and ceilings around the stairs and hall are lined to the fire rating asked for, and every door opening onto them becomes a fire door in a matching frame. That part is our description of the building work. Which measures apply to your house is the council's decision.
Do building regulations apply to an HMO conversion?
The building work has to comply in the usual way: new bathrooms and drainage, electrical work, structural changes and new partitions. There is also a wider test. Regulation 5 of the Building Regulations 2010 counts it as a material change of use when a building "contains a room for residential purposes, where previously it did not". The regulations define that as a room "which is not a dwelling-house or a flat and which is used by one or more persons to live and sleep". Whether the rooms in your HMO fall under it depends on how the house is let, so put the question to building control before work starts.
Keep the completion certificate. Our guides cover keeping building control records and what to do about work that was never signed off.
What building work does an HMO conversion involve?
It depends on the house and on the standard the council sets, but the list is drawn from these:
- partitions to form or resize bedrooms, boarded to the fire and sound rating asked for
- fire doors and frames along the escape route
- upgraded ceilings and stair enclosure
- extra shower rooms and WCs, with drainage and extract fans
- a kitchen sized and fitted for the number of sharers, and a second one past five people
- alarms, emergency lighting and extra sockets, by a registered electrician we arrange
- making good and decoration throughout
Sound between rooms matters to tenants even where no standard forces it. Our guide to resilient bars explains one way to cut noise through a ceiling.
What order should you do things in?
- Ask the council which licence the house will need for the number of people you plan to let to.
- Check planning, including any Article 4 direction, before you commit to the house or the design.
- Get the council's HMO standards for your type of letting and send them the floor plan.
- Draw the layout to those figures, counting floor area only where the ceiling is 1.5m or higher.
- Agree the route with building control.
- Build, with the inspections booked as the work goes on.
- Apply for the licence when the house is let. Camden says applications for properties with no tenants "may be returned".
What we do
Vayton Construction takes on HMO conversion and refurbishment work for landlords across London: partitions and fire-rated boarding, doors, bathrooms and kitchens, with the electrical work done by a registered electrician we arrange. We build to the layout and the standard your council has agreed, and we can price from your plans. Send the address, the borough, the number of rooms you are aiming for and any drawings or council letters you have. Our landlord refurbishment and drylining and ceilings pages show the trades involved. Send us the details to start.