Resilient bars: spacing, fixing and passing a sound test

November 19, 2026

A resilient bar is a thin steel channel that holds plasterboard off the studs or joists so less sound passes through. British Gypsum's spacing for walls and ceilings, how a resilient bar ceiling goes up, which way up the bars go, the screws that bridge them and the Part E sound targets.

November 19, 2026

Read the guide ↓

Prepared by Martynas Vaitaitis, Builder & Project Manager

Drawing of a resilient bar in section: the bar screwed to the underside of a joist, two layers of plasterboard screwed to the bar 16 mm below, and a board screw that stops short of the joist.

Diagram: a resilient bar holding the ceiling board 16 mm off the joist. Not to scale.

A resilient bar is a thin steel channel fixed across the studs of a wall or the joists of a ceiling, with the plasterboard screwed to the bar instead of to the frame. The bar flexes, so less of the vibration that carries sound passes from the frame into the board. Under a ceiling it holds the board 16 mm below the joists. It only works if no screw, pipe or fixing joins the board back to the frame behind it.

The figures here come from British Gypsum's Gypframe RB1 Resilient Bar pages, its White Book chapters on GypFloor Silent and GypWall Resilient, two of its system specifications and Approved Document E, all read on 19 November 2026. Other makers sell similar bars, sometimes called resilient channels, and each has its own fixing details.

What a resilient bar is

British Gypsum's RB1 is a typical bar: 3 m long, 16 mm deep and made from 0.45 mm steel, weighing 0.35 kg a metre and rated A1, the top class, for reaction to fire. One flange is screwed to the stud or joist and the board is screwed to the other face, 16 mm off the frame. British Gypsum describes it as isolating the plasterboard from the main structure to reduce sound induced vibration.

Resilient bar spacing

British Gypsum gives these maximum centres for RB1:

Where the bars goMaximum bar centres
Wall or partition600 mm
Wall finished with ceramic tiles400 mm
Ceiling under joists450 mm

British Gypsum calls those the usual maximums, and each system specification gives its own figure. On a GypWall Resilient wall the bars run horizontally across studs at 600 mm centres. Under a GypFloor Silent ceiling they run at right angles to the joists at up to 450 mm, with short lengths fitted between the rows around the edge of the room.

How a resilient bar ceiling is put up

GypFloor Silent is British Gypsum's upgrade for an existing timber joist floor, and its ceiling hangs on resilient bars. Its White Book chapter and specification C204006, for 45 x 195 mm joists at 450 mm centres, set out the ceiling side of the job like this. The full system also lays acoustic channels and plank over the joists from the room above.

  1. Check the joists. British Gypsum wants them reasonably level and straight, and where the underside is out it suggests a GypCeiling lining or an MF suspended ceiling instead. The upgrade adds weight, so it also asks for a structural engineer to check the joists.
  2. Fix the bars at right angles to the joists, no more than 450 mm apart, with 35 mm drywall screws into every joist, plus short lengths between the rows at the perimeter.
  3. Lay 100 mm of Isover Spacesaver Ready-Cut mineral wool between the joists so it rests on the bars.
  4. Screw two layers of 15 mm Gyproc SoundBloc to the bars: 25 mm screws for the first layer and 40 mm for the second, at no more than 230 mm centres, closing to 150 mm at board ends and round the edge of the ceiling.
  5. Seal the junctions with the walls using Gyproc Sealant. British Gypsum also advises boarding the ceiling before the walls are drylined or plastered, or else finishing it neatly against the wall.
Section along a timber joist with three resilient bars screwed to its underside and two layers of plasterboard screwed to the bars. Two board screws stop in the 16 mm gap; a third, too long, runs up into the joist.
Diagram: a resilient bar ceiling in section, with one screw long enough to bridge the bar. Bar shape simplified. Not to scale.

British Gypsum puts the finished ceiling 16 mm plus the boards below the joists, so 46 mm with two 15 mm boards. The floor above rises by 7 mm, and the sound figures British Gypsum gives are for the whole floor rather than the ceiling on its own.

The screw that bridges the bar

British Gypsum repeats one rule in its ceiling and wall chapters: the screws holding the board must not touch the joists or studs. For ceilings it says to use the correct length screws "to ensure the screws do not contact the timber joists". A screw that reaches the frame gives sound a solid path straight round the bar.

Anything else that links the board to the frame, or one face of a wall to the other, does the same. British Gypsum warns against services and fixtures that bridge between the linings on each side, and asks for every air path to be sealed. Our own site checks follow from that:

  • screws of the lengths in the specification, checked before the first board goes up
  • no extra screws into the joists to pull a sagging board tight
  • pipes and cables kept off the back of the board
  • sealant round the edges, which on a wall goes on the first layer of board on the side with the bars
  • downlights planned before boarding, because Approved Document E notes that recessed light fittings in its ceiling treatments can reduce the sound insulation. A registered electrician we arrange fits them to the approach the ceiling designer sets.

Which way up does a resilient bar go?

On British Gypsum's GypWall Resilient metal stud wall, the bars are normally fixed with the base flange on the top side, except the highest one, which goes base flange down so the board can be fixed at the head. The other rules for that wall are:

  • bars run across the studs, and where two meet they are nested one into the other over a stud
  • extra bars run vertically on the end studs at walls and door openings, to take the board's edge fixings
  • where a bar runs along the foot of the wall, a timber nogging goes under it so the skirting does not trap it
  • with bars on one side only, that side is 16 mm deeper, so the wall is not symmetrical on plan
Elevation of a metal stud wall at 600 mm centres with resilient bars running across the studs, the top bar turned base flange down, a vertical bar on the end stud against the masonry wall, a nested join over a stud and a timber nogging behind the skirting.
Diagram: resilient bars on a GypWall Resilient wall, following British Gypsum's fixing rules. Not to scale.

These rules come from the wall system. British Gypsum's ceiling chapter gives no direction for the bar, so follow the drawings for the ceiling system you are building.

A worked example from that wall: specification A316011 has 70 mm studs, bars on one side, 19 mm Gyproc Plank under 12.5 mm SoundBloc on both faces and 50 mm of insulation. The bars are fixed with 13 mm wafer head screws, and the boards with 35 mm screws for the plank and 45 mm for the outer layer. British Gypsum rates it at Rw 63 dB in the laboratory. Where the head of this wall needs a deflection head because the floor above moves, British Gypsum says the sound insulation drops only slightly.

Fixing shelves and cupboards to a resilient bar wall

On GypWall Resilient, British Gypsum puts medium and heavy fixtures only on boards fixed straight to the studs, which means the face without bars, and warns that the fixings themselves can lower the sound insulation. If both faces need cupboards, it suggests a twin frame wall instead. Our guide to pattressing a metal stud wall covers the backing that goes in before the board.

Will resilient bars pass a sound test?

They can, as part of a complete tested system, but only the test on site decides. Approved Document E calls for testing in new homes and conversions alike, on the properties building control selects, and its only exemption is Robust Details in new builds. These are the targets it sets, measured once the work is finished:

Separating wall or floorTarget on site
Wall between new homesAt least 45 dB airborne
Floor between new homesAt least 45 dB airborne, at most 62 dB impact
Wall in a conversion to flatsAt least 43 dB airborne
Floor in a conversion to flatsAt least 43 dB airborne, at most 64 dB impact

Airborne sound is measured as DnT,w + Ctr and impact sound as L'nT,w. A higher airborne figure is better, while the impact figure has to stay below its limit.

We have fitted resilient bar ceilings in flats, and they passed their sound tests. A pass still belongs to the whole floor and ceiling, so every new job is tested on its own.

Approved Document E does name plasterboard on resilient bars, as ceiling treatment B, but in its section on new buildings. For flats formed by a conversion its own floor examples are an independent ceiling, with at least 125 mm between the top of the new ceiling and the old floor, or a platform floor laid on top. British Gypsum says GypFloor Silent is designed for conversions. Whichever construction is chosen, a separating floor in a conversion is still tested before completion.

Laboratory ratings run higher than site results, because a real building also lets sound round the sides through the walls and floors it joins, which is called flanking. British Gypsum's own table for walls in a conversion pairs the 43 dB site target with a laboratory Rw + Ctr of 47 dB as the minimum and 52 dB as its recommendation, and says the minimum leaves little or no margin. Its floor C204006 is rated Rw + Ctr 48 dB and Ln,w 56 dB in the laboratory. For the floors, it suggests an acoustic lining on any supporting wall lighter than 365 kg/m².

Resilient bars or another kind of ceiling?

CeilingDepth and trade off
Resilient bars16 mm plus the boards below the joists, and a screw into a joist bridges it
Independent ceiling on its own joistsAt least 125 mm from the old floor to the top of the new ceiling, so it needs spare room height
MF ceiling on acoustic hangersHung from the structure on a steel grid, with the void set by the hanger length
Platform floorA floating layer of board on at least 25 mm of dense mineral wool, laid from the room above, which raises its floor

Our guide to MF ceilings and bulkheads covers the grid and its hangers.

Old lath and plaster ceilings

Where an existing lath and plaster ceiling stays and a fire rating is needed, British Gypsum's GypFloor Silent chapter has it underdrawn with chicken wire, fixed to the wire maker's instructions. A cavity is then formed with battens of at least 38 x 38 mm, or a GypCeiling lining, before the new ceiling goes on. Our guide to lath and plaster explains how to tell what you have.

Resilient bars on a timber stud wall

The bars suit timber studs as well. British Gypsum's timber partition A046005 pairs 600 mm studs with bars on one face, double SoundBloc on both faces and 50 mm of acoustic roll, for Rw 55 dB. Our guide to stud wall spacing covers the frame itself.

Getting resilient bars fitted

Our engineer's first visit is free and you are under no obligation. Tell us whether the wall or floor separates two homes, whether building control will ask for a sound test, the joist size and spacing, and how much ceiling height you can give up. We then name the system, the bar centres, the boards and the screw lengths, and build to the maker's specification. For the wider picture, see our acoustic partitions and drylining and ceilings pages, or send us the drawings to start. Keep the sound test results with your building control completion records.